Four strips land on your desk, and they look like the same slow, skipped rhythm. The difference between a block you watch and a block that needs a pacer hides in two habits: measuring the PR interval on every beat, and counting P waves against QRS complexes. This heart blocks ecg comparison walks through 16 strip differences, four for each AV block, so first-degree, Wenckebach, Mobitz II and complete heart block separate cleanly.
Work through the blocks in order, because each round adds one clue to the round before it. The basics behind every strip here match the MedlinePlus heart block overview, so the values below are the ones your instructors expect. Keep calipers nearby, and say each measurement out loud before you scroll on.
| Course | ECG & Cardiac |
| Best for | Nursing students telling the four AV blocks apart on strips |
| Study time | About 20 minutes |
First-Degree: The Fixed Long PR

First-degree block is the gentlest slowdown here: every signal still gets through the AV node, just late. The diagnosis sits in one measurement; this strip is where your PR habit starts.
- What it is: An AV node delay stretches the PR interval past 0.20 seconds, yet every atrial impulse still conducts, so no beat is ever dropped.
- Key numbers: Rate normal, rhythm regular; one P wave before every QRS; PR fixed at 0.28 seconds on every beat, well over the 0.20 second limit; QRS narrow, under 0.12 seconds.
- Nursing priority: Chart the PR and recheck it on strips; a PR that keeps lengthening can be the sign of a worsening block.
First-Degree: Every P Still Conducts

The second difference is what does not happen: no dropped beats. Each P wave is followed, after its long pause at the node, by a QRS, and that unbroken one-to-one pattern separates first-degree block from both second-degree types.
- Count the pairs: Walk the strip and match every P wave to the QRS that follows it; in first-degree block the count comes out even.
- Watch the spacing: The P-to-QRS gap is long but never changes, so the rhythm stays calm and regular.
- Know the contrast: Once a P wave stands alone with no QRS behind it, the strip is a second-degree block.
First-Degree: A Normal-Looking Rate and Rhythm

Strip three fools many students because almost everything looks ordinary. Rate, rhythm and QRS width sit in their normal lanes; only the PR interval gives the block away, so a calm strip still earns a measurement before you move on to skills like heart sounds and murmurs in your assessment practice.
- What it is: A first-degree block inside an otherwise normal tracing: normal rate, regular rhythm, narrow QRS, PR quietly parked above 0.20 seconds.
- Key signs: Nothing looks dramatic: P waves march evenly, each QRS follows after its PR, and the complexes keep their narrow shape.
- Nursing priority: Measure the PR on every ECG you read, even when the strip looks normal, so a quiet delay never slips past unrecorded.
First-Degree: Found on Paper, Rarely Felt

The last first-degree difference lives off the strip: the patient usually feels nothing. Most of these blocks turn up by accident on a routine ECG, in athletes, older adults, and patients whose medicines slow the AV node.
- Blame the usual causes: Aging conduction tissue, beta blockers and digoxin slow the AV node and stretch the PR without dropping a beat.
- Expect no symptoms: Every impulse conducts, so the rate holds steady and dizziness or fainting stay out of the picture.
- Monitor, do not panic: The job is trending the PR and flagging new node-slowing medicines, not urgent treatment.
Study tip: Read every strip in one order: rate, rhythm, P wave, PR interval, QRS width. A fixed order stops your eyes jumping to the dramatic beat and missing the pattern.
Wenckebach: The PR That Keeps Growing

Wenckebach, also called second-degree type I block, announces itself with a PR that refuses to sit still. Each beat waits longer at the node than the last, until one impulse does not get through at all.
- What it is: A block inside the AV node: conduction slows beat by beat until one P wave is blocked.
- Key numbers: Rate slower across each cycle, since one beat drops; rhythm irregular in repeating pattern; a P wave for every beat, one of them not followed by a QRS; PR growing from 0.24 to 0.32 to 0.40 seconds before the drop; QRS narrow, under 0.12 seconds.
- Nursing priority: Note the pattern and symptoms, and report it: Wenckebach is often temporary, but new dizziness changes the picture fast.
Wenckebach: The Dropped Beat

The dropped beat is the moment this block signs its name. After a few beats of growing PR intervals, a P wave appears with nothing behind it, the ventricles rest, and the sequence restarts.
- Spot the empty space: Find the P wave standing alone; the pause after it is the longest gap, and it ends the cycle.
- Check what restarts: The first beat after the pause carries the group’s shortest PR, because the node had a full cycle to recover.
- Do not call it a pause problem: One dropped beat inside a lengthening pattern is Wenckebach; dropped beats with a fixed PR belong to Mobitz II.
Wenckebach: Grouped Beats, Repeating Cycle

Wenckebach strips fall into groups: three or four QRS complexes travel together, then a pause, then the group forms again. Grouped beating is a fast clue before you measure anything, and sets like ecg practice strips train your eye to catch it at a glance.
- What it is: Grouped beating: clusters of conducted beats, a pause with one QRS missing, the same shape repeating.
- Key signs: The pause runs shorter than two full P-to-P cycles, the groups look alike, and the PR grows in the same order inside each group.
- Nursing priority: Describe the pattern in your note, cycles and all, rather than charting a lone rate; the pattern is what the provider needs.
Wenckebach: Narrow QRS, Node-Level Block

The QRS in Wenckebach usually stays narrow, and that width tells you where the block lives. Past the node, the impulse travels the normal fast pathways through the ventricles.
- Read the width: Measure the QRS under 0.12 seconds on conducted beats; that width points the block upward, at the node.
- Expect the better outcome: Node-level blocks come and go with vagal tone, sleep or medicines, and Wenckebach has the best outlook of the second-degree blocks.
- Still watch the patient: A benign pattern never excuses symptoms, so pair every strip with a blood pressure, a pulse check and a symptom review.
Mobitz II: Fixed PR, Sudden Drop

Mobitz II, the other second-degree block, plays by colder rules. The PR on conducted beats never changes; then, with no build-up, a P wave fires and no QRS follows.
- What it is: A block below the AV node, in the His-Purkinje system or bundle branches, where impulses fail suddenly instead of slowing first.
- Key numbers: Rate slower than the atrial rate; rhythm regular or irregular by conduction ratio; more P waves than QRS complexes; PR fixed on conducted beats; QRS wide at 0.14 seconds, past the 0.12 limit.
- Nursing priority: Treat new Mobitz II as urgent news: it can step down into complete heart block with no warning strip.
Mobitz II: More P Waves Than QRS

Count the waves on a Mobitz II strip and the mismatch is the message. P waves keep their steady march, but only some earn a QRS, in patterns like two P waves for every one QRS.
- Name the ratio: Chart conduction as 2:1 or 3:1, P waves to QRS complexes, so the team hears how many impulses get through.
- Test the conducted beats: On every conducted beat, the PR sits at one fixed value, the cleanest way to separate Mobitz II from Wenckebach.
- Feel the pulse gap: The pulse you feel matches the QRS count, not the P count, so the rate runs slower than the atria fire.
Mobitz II: Wide QRS, Low Block

A wide QRS points below the node. With the block in the bundle branches, the ventricles activate cell to cell and the complex stretches past 0.12 seconds. Width alone never names a block, though; the peaked T waves taught in hyperkalemia ecg changes are a separate wide-complex look-alike to rule out.
- What it is: An infranodal block: the failure sits in the His-Purkinje system or bundle branches, downstream of the node, in tissue with no gentle slowdown mode.
- Key signs: Wide QRS on conducted beats, a fixed PR, sudden dropped beats, and a strip that looks calm between drops.
- Nursing priority: Flag the rhythm promptly and expect a pacemaker evaluation; a block this low rarely improves and often needs a device.
Mobitz II: No Warning Before the Drop

The last Mobitz II difference is the missing warning. Wenckebach builds to its dropped beat over a few cycles; Mobitz II gives nothing: one beat conducts, the next does not, and the patient may feel the gap as a faint.
- Know why atropine disappoints: Atropine speeds the AV node; this block sits below it, so the drug often changes nothing here or in complete block.
- Watch for the step down: Dropped beats can multiply as the block advances, turning a 2:1 pattern into ventricular pauses or complete block.
- Put symptoms first: Syncope, chest discomfort or falling blood pressure with this rhythm means an urgent call, not a strip in fifteen minutes.
Red flag: A Mobitz II strip in a patient who feels faint, dizzy or short of breath means an urgent call to the provider. This block can drop into complete heart block without warning, and the ventricles may not rescue the rate.
Complete Block: Two Independent Rhythms

Complete heart block, the third-degree block, is a total divorce between the chambers. The node lets nothing through, so the atria follow the sinus node while the ventricles rescue themselves with a slow escape rhythm.
- What it is: Third-degree AV block: no atrial impulse reaches the ventricles, AV dissociation, each chamber beating on its own clock.
- Key numbers: Atrial rate about 75 per minute against a ventricular rate of about 40; rhythm: P-P and R-R each regular but marching independently; a P wave lands before some QRS complexes only by coincidence; the PR never repeats; QRS narrow or wide, by escape site.
- Nursing priority: Judge the patient by the ventricular rate: check blood pressure and symptoms, call the provider, and expect pacing.
Complete Block: Atria Outrun Ventricles

Lay the two rates side by side and complete block cannot hide. The atria fire at a normal sinus pace while the ventricles crawl underneath, and neither rate adjusts to meet the other.
- Count two rates: Count P waves for the atrial rate and QRS complexes for the ventricular rate; in complete block the two numbers refuse to match.
- March the P waves: P waves keep perfect time through the strip, walking in and out of QRS complexes and T waves undisturbed.
- Distrust the pulse: The wrist pulse reports only the ventricular rate, so a calm atrial rate never means the patient is perfusing well.
Complete Block: The Escape Rhythm Sets the Rate

When the ventricles take over, its speed and width say where the rescue started. A junctional pacer sits just below the block and fires faster and narrower; a ventricular pacer sits lower, fires slower and is far less dependable, a contrast worth pinning beside an ecg rhythm strips cheat sheet for review.
- What it is: An escape rhythm: a pacemaker below the block that keeps the ventricles beating when no impulse can reach them.
- Key signs: A junctional escape runs 40 to 60 per minute, narrow QRS; a ventricular escape runs 20 to 40 per minute, wide QRS; slower plus wider means less reliable.
- Nursing priority: Report a slow, wide escape rhythm as the least stable picture: keep the patient in bed, monitor continuously, prepare for pacing.
Complete Block: Steady Spaces, No Relationship

The final difference is a paradox: everything on a complete block strip is regular, and nothing is related. P-P spaces match each other, R-R spaces match each other, and the PR takes a new value on every beat.
- Measure the spaces: Calipers show equal P-P and R-R intervals, two regular rhythms that make this block look tidy at first glance.
- Chase the PR: Measure the PR on five beats in a row and you get five different numbers, because no P wave here ever conducted.
- Close with the patient: A ventricular rate in the 30s or 40s explains dizziness, fainting and low blood pressure, so the last check is the person, not the paper.
The Short Version
If you remember one thing: the PR interval and the P-to-QRS count name every block here, a fixed long PR for first-degree, a growing PR for Wenckebach, a fixed PR with sudden drops for Mobitz II, and no relationship for complete block.
Study the blocks as two pairs: the node-level pair, first-degree and Wenckebach, against the low pair, Mobitz II and complete block. Ten strips a night with a ruler makes the split automatic within a week.